Send Message

6KV Low Smoke Halogen Free Cable

Basic Information
Place of Origin: CHINA
Brand Name: DONGJIAXIN
Certification: IEC, Rosh,CCC
Model Number: YJV22-3.6/6-3C
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: Steel wooden drum
Delivery Time: 7-15 working days
Payment Terms: L/C, T/T
Supply Ability: 100KM/Week
Model Name: YJV22-3.6/6-3C Rated Voltage: 0.6/1kV
Specification: 1.5~600mm2 Insulator: XLPE
Conductor Type: Stranded Bear Copper Class2 Sheath: Pvc
Application: Industrial , Home Appliance , Low Voltage Installation System,
High Light:

6KV low smoke halogen free cable

,

3.6KV low smoke halogen free cable

Steel Tape Armoured Low Smoke Zero Halogen Cable For Power Distribution 3.6/ 6 KV

Low Smoke Halogen Free Cable

 

3,6/ 6 kV 3 core XLPE Insulated LSZH SHEATHED Steel Tape Armoured 3 core

Annealed Stranded Copper Conductor,XLPE Insulation,Copper Tape Screened, Core laid up, PVC Innersheathed, Armoured and PVC outer sheathed power cable.

The 3 cores cables are designed for distribution of electrical power with nominal voltage Uo/ U:3.6/6 KV and frequency 50Hz.

Steel Tape Armoured Low Smoke Zero Halogen Cable For Power Distribution 3.6/ 6 KV 0

CONSTRUCTION:

1. CONDUCTOR

– Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

– Inner semi-conducting coating

3. INSULATION

– Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

– Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

– copper tapes helically with a minimum thickness of 0,1 mm.

6. FILLER

– PP filler

7. WRAPPING TAPE

INNER SHEATH

– LSZH Compound

ARMOR WITH

Galvanized Double Steel Tape minimum thickness of 0,1 mm

8. SHEATH

– Outer sheath of LSZH compound

Core identification:

colored tapes under screen.

Steel Tape Armoured Low Smoke Zero Halogen Cable For Power Distribution 3.6/ 6 KV 1

STANDER

International:IEC60502-2

National:GB/T 12706.1-2008

TECHNICAL DATA

Temperature range
– during installation up to -5°C

 

Operating temperature
– max. +90°C

 

Short circuit temperature
+250°C (short circuit duration max. 5 s)

 

Minimum bending radius
– 15 x cable Ø

Nominal voltage
– U0/U 3.6/6 kV

Operating voltage, 50 Hz
– for 3.6/6 kV = max. 7.2 kV

Test voltage(V/5 min)
– for3.6/6 kV = 12 kV

Breaking strength:

– min. 200%
Tensile strength:

– min. 12,5 N/mm2

3.6/ 6 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

No.cores x
cross-sec.
Insulation
thickness
Inner Sheath
thickness
Sheath
thickness
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃
mm² mm mm mm mm kg / km A A
3 x 35 2.5 1.3 2.3 43.5 2993 144 181
3 x 50 2.5 1.3 2.4 46.5 3601 172 215
3 x 70 2.5 1.4 2.5 49.3 4368 213 263
3 x 95 2.5 1.4 2.6 54.3 5348 261 315
3 x 120 2.5 1.5 2.8 57.9 6303 301 358
3 x 150 2.5 1.6 2.9 61.7 7405 341 402
3 x 185 2.5 1.6 3.0 65.4 8646 392 456
3 x 240 2.6 1.7 3.2 70.7 10573 459 527
3 x 300 2.8 1.8 3.4 77.3 12779 532 599
3 x 400 3.0 2.0 3.7 88.1 17225 624 685

*Dimensions and specifications may be changed without prior notice.

MEDIUM VOLTAGE CABLE TESTING

Routine tests: Sample tests: Type tests:
These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath
These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test
These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.
 
▼ Standards&Certificates:

  International: IEC 60502-1
National:GB/ T 12706.1-2008

Packing&Delivery:

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

Copper Cable ZR YJV22 0.6/1kv XLPE Insulated Steel Tape Armoured FR PVC Underground Power Cable
▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 4 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300
 

 

▼ Delivery Port :

Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 5 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 6 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 7
Port of Shenzhen Port of Hongkong

Port of Guangzhou
 

 

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 6.0 12.1
1×2.5 1 0.7 1.4 6.4 7.41
1×4 1 0.7 1.4 6.9 4.61
1×6 1 0.7 1.4 7.3 3.08
1×10 7 0.7 1.4 8.4 1.83
1×16 7 0.7 1.4 9.4 1.15
1×25 7 0.9 1.4 11.0 0.727
1×35 7 0.9 1.4 12.0 0.524
1×50 10 1.0 1.4 13.3 0.387
1×70 14 1.1 1.4 15.1 0.268
1×95 19 1.1 1.5 17.3 0.193
1×120 24 1.2 1.5 19.0 0.153
1×150 30 1.4 1.6 20.9 0.124
1×185 37 1.6 1.6 23.0 0.0991
1×240 48 1.7 1.7 25.7 0.0754
1×300 61 1.8 1.8 28.3 0.0601
1×400 61 2.0 1.9 31.6 0.0470
1×500 61 2.2 2.0 35.1 0.0366
1×630 61 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

 

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 10.6 12.1
2×2.5 1 0.7 1.8 11.4 7.41
2×4 1 0.7 1.8 12.4 4.61
2×6 1 0.7 1.8 13.2 3.08
2×10 7 0.7 1.8 15.4 1.83
2×16 7 0.7 1.8 17.4 1.15
2×25 7 0.9 1.8 20.6 0.727
2×35 7 0.9 1.8 22.6 0.524
2×50 10 1.0 1.8 26.2 0.387
2×70 14 1.1 1.8 29.8 0.268
2×95 19 1.1 1.9 34.0 0.193
2×120 24 1.2 2.0 37.4 0.153
2×150 30 1.4 2.2 41.2 0.124
2×185 37 1.6 2.3 45.6 0.0991
2×240 48 1.7 2.5 51.0 0.0754
2×300 61 1.8 2.6 56.0 0.0601
2×400 61 2.0 2.9 62.6 0.0470
2×500 61 2.2 3.1 70.0 0.0366
2×630 61 2.4 3.3 83.6 0.0283
3×1.5 1 0.7 1.8 11.2 12.1
3×2.5 1 0.7 1.8 12.1 7.41
3×4 1 0.7 1.8 13.2 4.61
3×6 1 0.7 1.8 14.0 3.08
3×10 7 0.7 1.8 16.4 1.83
3×16 7 0.7 1.8 18.6 1.15
3×25 7 0.9 1.8 22.0 0.727
3×35 7 0.9 1.8 24.2 0.524
3×50 10 1.0 1.8 28.0 0.387
3×70 14 1.1 1.9 32.1 0.268
3×95 19 1.1 2.0 36.4 0.193
3×120 24 1.2 2.1 40.3 0.153
3×150 30 1.4 2.3 44.3 0.124
3×185 37 1.6 2.4 49.1 0.0991
3×240 48 1.7 2.6 54.9 0.0754
3×300 61 1.8 2.7 60.1 0.0601
3×400 61 2.0 3.0 67.4 0.0470
3×500 61 2.2 3.2 75.3 0.0366
3×630 61 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 12.2 12.1
4×2.5 1 0.7 1.8 13.1 7.41
4×4 1 0.7 1.8 14.3 4.61
4×6 1 0.7 1.8 15.3 3.08
4×10 7 0.7 1.8 18.0 1.83
4×16 7 0.7 1.8 20.4 1.15
4×25 7 0.9 1.8 24.3 0.727
4×35 7 0.9 1.8 26.7 0.524
4×50 10 1.0 1.8 30.8 0.387
4×70 14 1.1 2.0 35.4 0.268
4×95 19 1.1 2.1 40.4 0.193
4×120 24 1.2 2.3 44.9 0.153
4×150 30 1.4 2.4 49.3 0.124
4×185 37 1.6 2.6 54.7 0.0991
4×240 48 1.7 2.8 61.0 0.0754
4×300 61 1.8 3.0 67.2 0.0601
4×400 61 2.0 3.3 75.3 0.0470
4×500 61 2.2 3.5 84.0 0.0366
4×630 61 2.4 3.8 100.5 0.0283
5×1.5 1 0.7 1.8 13.2 12.1
5×2.5 1 0.7 1.8 14.2 7.41
5×4 1 0.7 1.8 15.6 4.61
5×6 1 0.7 1.8 16.7 3.08
5×10 7 0.7 1.8 19.6 1.83
5×16 7 0.7 1.8 22.3 1.15
5×25 7 0.9 1.8 26.7 0.727
5×35 7 0.9 1.8 29.4 0.524
5×50 10 1.0 1.9 34.1 0.387
5×70 14 1.1 2.1 39.1 0.268
5×95 19 1.1 2.2 44.7 0.193
5×120 24 1.2 2.4 49.7 0.153
5×150 30 1.4 2.6 54.7 0.124
5×185 37 1.6 2.8 60.6 0.0991
5×240 48 1.7 3.0 67.7 0.0754
5×300 61 1.8 3.2 74.6 0.0601
5×400 61 2.0 3.5 83.4 0.0470
5×500 61 2.2 3.8 93.4 0.0366
5×630 61 2.4 4.1 111.7 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 12.9 7.41
3×4+1×2.5 1 0.7 1.8 14.0 4.61
3×6+1×4 1 0.7 1.8 15.1 3.08
3×10+1×6 7 0.7 1.8 17.3 1.83
3×16+1×10 7 0.7 1.8 19.8 1.15
3×25+1×16 7 0.9 1.8 23.3 0.727
3×35+1×16 7 0.9 1.8 25.1 0.524
3×50+1×25 10 1.0 1.8 29.4 0.387
3×70+1×35 14 1.1 1.9 33.5 0.268
3×95+1×50 19 1.1 2.1 38.1 0.193
3×120+1×70 24 1.2 2.2 42.5 0.153
3×150+1×70 30 1.4 2.3 45.8 0.124
3×185+1×95 37 1.6 2.5 51.2 0.0991
3×240+1×120 48 1.7 2.6 57.0 0.0754
3×300+1×150 61 1.8 2.8 62.6 0.0601
3×400+1×185 61 2.0 3.1 70.1 0.0470
3×500+1×240 61 2.2 3.3 78.3 0.0366
3×630+1×300 61 2.4 3.6 92.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 13.8 7.41
3×4+2×2.5 1 0.7 1.8 15.1 4.61
3×6+2×4 1 0.7 1.8 16.2 3.08
3×10+2×6 7 0.7 1.8 18.5 1.83
3×16+2×10 7 0.7 1.8 21.3 1.15
3×25+2×16 7 0.9 1.8 24.9 0.727
3×35+2×16 7 0.9 1.8 26.6 0.524
3×50+2×25 10 1.0 1.8 31.4 0.387
3×70+2×35 14 1.1 2.0 35.6 0.268
3×95+2×50 19 1.1 2.1 40.4 0.193
3×120+2×70 24 1.2 2.3 45.5 0.153
3×150+2×70 30 1.4 2.4 48.5 0.124
3×185+2×95 37 1.6 2.5 54.2 0.0991
3×240+2×120 48 1.7 2.7 60.3 0.0754
3×300+2×150 61 1.8 2.9 66.5 0.0601
3×400+2×185 61 2.0 3.2 74.3 0.0470
3×500+2×240 61 2.2 3.5 83.1 0.0366
3×630+2×300 61 2.4 3.8 97.0 0.0283

 

Tag:   fireproof electrical cable,    fire rated electrical cable,    fire resistant power cable

 

Ordering Options:
For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :

1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material : PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

6KV Low Smoke Halogen Free Cable 7

 

6KV Low Smoke Halogen Free Cable 8

 

 

 

FAQ

* How to assure the quality of products?

1. Most of our products have certification.

2. Our Lab staff will test the material and check the process card before production.

3. The O.D tester is testing all the time during production, and the production line is always under control.

4. The product will be tested by Lab staff after production.

* Do you offer free samples or not?

1. If we have inventory about the sample you need and the total amount is not large, it's free.

2. If we don't have inventory, according to our company's rule, sample and freight costs need to be paid by your esteemed company. And we will return the sample cost to you when you place the first order with us. Thanks for your support.

* When I want customized products, how to do it?

We have professional equipment, technicians & skilled employees, OEM & customized service is welcome. Drawings or samples are required. Of course, the purchased quantity should meet our MOQ.

Contact Details
Coco

Phone Number : +8613528796850

WhatsApp : +8613528796850